Operator's Manual: Models CB-3500 & CB-5000
10-6
PROBLEM POSSIBLE CAUSE(S) POSSIBLE ACTION(S)
Pump will not prime and Pump
motor is running.
1. ere is a leak(s) in the suction
line.
2. e pump is not installed so it will
ll with oil during the priming
process.
3. e pump gears are dry.
4. e pump seal is damaged.
5. e ball valve is closed.
6. e canister lter is dirty.
7. e check valve is dirty.
8. e pump is damaged or worn out.
1. Follow the specications in Section
4 to make sure the suction line
is installed properly and that all
ttings are 100% airtight.
2. Make sure the pump head is lled
with oil prior to starting the pump.
See Section 5.
3. Follow the procedure in Section
5 to ll the oil line and prime the
pump.
4. With the pump not running, wipe
your nger along the bottom of the
cylinder at the pump sha. If there
is oil at the pump sha, the seal is
damaged. Replace the pump, or
replace the seal.
NOTE: Some oils will expand as
they warm up. Because there is
a check valve in the suction line,
the expanding oil may build up
pressure and damage the oil seal.
Install a mini-accumulator in the
1/8” port of the canister lter to
prevent the pressure build-up.
5. Open the ball valve on the suction
line.
6. Refer to Section 9 to clean the
canister lter.
7. Refer to Section 9 to clean the
check valve.
8. Replace the pump